Anatomical Models for Radiation Dosimetry / Edition 1

Hardcover (Print)
Used and New from Other Sellers
Used and New from Other Sellers
from $55.01
Usually ships in 1-2 business days
(Save 64%)
Other sellers (Hardcover)
  • All (7) from $55.01   
  • New (4) from $126.66   
  • Used (3) from $55.01   

Overview

Over the past few decades, the radiological science community has developed and applied numerous models of the human body for radiation protection, diagnostic imaging, and nuclear medicine therapy. The Handbook of Anatomical Models for Radiation Dosimetry provides a comprehensive review of the development and application of these computational models, known as "phantoms."

An ambitious and unparalleled project, this pioneering work is the result of several years of planning and preparation involving 64 authors from across the world. It brings together recommendations and information sanctioned by the International Commission on Radiological Protection (ICRP) and documents 40 years of history and the progress of those involved with cutting-edge work with Monte Carlo Codes and radiation protection dosimetry. This volume was in part spurred on by the ICRP’s key decision to adopt voxelized computational phantoms as standards for radiation protection purposes. It is an invaluable reference for those working in that area as well as those employing or developing anatomical models for a a number of clinical applications.

Assembling the work of nearly all major phantom developers around the world, this volume examines:

  • The history of the research and development in computational phantoms
  • Detailed accounts for each of the well-known phantoms, including the MIRD-5, GSF Voxel Family Phantoms, NCAT, UF Hybrid Pediatric Phantoms, VIP-Man, and the latest ICRP Reference Phantoms
  • Physical phantoms for experimental radiation dosimetry
  • The smallest voxel size (0.2 mm), phantoms developed from the Chinese Visible Human Project
  • Applications for radiation protection dosimetry involving environmental, nuclear power plant, and internal contamination exposures

  • Medical applications, including nuclear medicine therapy, CT examinations, x-ray radiological image optimization, nuclear medicine imaging, external photon and proton treatments, and management of respiration in modern image-guided radiation treatment
  • Patient-specific phantoms used for radiation treatment planning involving two Monte Carlo code systems: GEANT4 and EGS
  • Future needs for research and development

Related data sets are available for download on the authors’ website. The breadth and depth of this work enables readers to obtain a unique sense of the complete scientific process in computational phantom development, from the conception of an idea, to the identification of original anatomical data, to solutions of various computing problems, and finally, to the ownership and sharing of results in this groundbreaking field that holds so much promise.

Read More Show Less

Product Details

Meet the Author

Dr. X. George Xu is a professor of nuclear engineering and biomedical engineering at Rensselaer Polytechnic Institute (RPI), Troy, New York. Dr. Keith F. Eckerman is the leader of the Dosimetry Research Team in the Environmental Science Division at the Oak Ridge National Laboratory (ORNL).

Read More Show Less

Table of Contents

Part I

Computational Phantoms for Radiation Dosimetry: A 40 Year History of Evolution, X. G. Xu

Stylized Computational Phantoms Developed at ORNL and Elsewhere, K. F. Eckerman, J. W. Poston Sr., W. E. Bolch, and X. G. Xu

The GSF Voxel Computational Phantom Family, M. Zankl

The ADELAIDE Teenage Female Voxel Computational Phantom, M. Caon, G. Bibbo, and J. E. Pattison

The MCAT, NCAT, XCAT, and MOBY Computational Human and Mouse Phantoms, W. P. Segars and B. M. W. Tsui

The 3D and 4D VIP-Man Computational Phantoms, X. G. Xu, T.-C. E. Chao, A. Bozkurt, C. Shi, and J. Zhang

The FAX06 and the MAX06 Computational Voxel Phantoms, R. Kramer, H. J. Khoury, J. W. Vieira, V. J. de Melo Lima, E. C. de Miranda Loureiro, G. Hoff, and I. Kawrakow

The University of Florida Pediatric Phantom Series, C. Lee, D. L. Lodwick, D. H. Pafundi, S. R. Whalen, J. L. Williams, and W. E. Bolch

Japanese Computational Phantoms: Otoko, Onago, JM, JM2, JF, TARO, HANAKO, Pregnant Woman, and Deformable Child, K. Saito, K. Sato, S. Kinase, and T. Nagaoka

Korean Computational Phantoms: KMIRD, KORMAN, KORWOMAN, KTMAN-1, KTMAN-2, and HDRK-Man, C. Lee and C. H. Kim

Chinese Voxel Computational Phantoms: CNMAN, VCH, and CVP, B. Zhang, J. Ma, G. Zhang, Q. Liu, R. Qiu, and J. Li

Pregnant Female/Fetus Computational Phantoms and the Latest RPI-P Series Representing 3, 6, and 9 Months Gestational Periods, X. G. Xu, C. Shi, M. G. Stabin, and V. Taranenko

The Vanderbilt University Reference Adult and Pediatric Phantom Series, M. G. Stabin, M. A. Emmons-Keenan, W. P. Segars, and M. J. Fernald

Mesh-Based and Anatomically Adjustable Adult Phantoms and a Case Study in Virtual Calibration of Lung Counter for Female Workers, Y. H. Na, J. Zhang, A. Ding, and X. G. Xu

The ICRP Reference Computational Phantoms, M. Zankl, K. F. Eckerman, and W. E. Bolch

Physical Phantoms for Experimental Radiation Dosimetry, D. E. Hintenlang, W. E. Moloney, and J. Winslow

Part II

Applications to Environmental Exposures, N. Petoussi-Henss and K. Saito

Applications to External Radiation Exposures in Nuclear Power Plants, W. D. Reece, C. H. Kim, and X. G. Xu

Applications to Bioassay for Internal Radiation Contamination, G. H. Kramer

Applications to Nuclear Medicine, M. G. Stabin and M. Bardiès

Applications to Computed Tomography for Pediatric Patients, W. E. Bolch, C. Lee, C. Lee, J. Hurtado, and J. L. Williams

Applications to Computed Tomography for Adult Patients, J. J. DeMarco and M. McNitt-Gray

Applications to Optimization of X-Ray Radiographic Imaging, B. Yazıcı, I.-Y. Son, A. Jin, and X. G. Xu

Applications to Nuclear Medicine Imaging and Dosimetry Involving MCAT, NCAT, and MOBY Phantoms, B. M. W. Tsui and W. P. Segars

Applications to Secondary Radiation Dosimetry in External Beam Radiation Therapy, H. Paganetti

Applications to Image-Guided Radiation Treatment Planning, C. Shi, M. Fuss, N. Papanikolaou, and X. G. Xu

Dose Calculations in Radiation Therapy Based on Patient Models Using the Geant4 Monte Carlo Code, H. Paganetti

Applications to Patient-Specific Voxel Computational Phantoms in EGS Monte Carlo Codes for Radiation Treatment Involving Photons and Electrons, C.-M. C. Ma

Applications to Nonionizing Radiation Protection, J. Chen, W. Kainz, and D. Wu

Summary and Future Needs Related to Computational Phantoms, X. G. Xu, M. G. Stabin, W. E. Bolch, and W. P. Segars

About the Contributors

Index

Read More Show Less

Customer Reviews

Be the first to write a review
( 0 )
Rating Distribution

5 Star

(0)

4 Star

(0)

3 Star

(0)

2 Star

(0)

1 Star

(0)

Your Rating:

Your Name: Create a Pen Name or

Barnes & Noble.com Review Rules

Our reader reviews allow you to share your comments on titles you liked, or didn't, with others. By submitting an online review, you are representing to Barnes & Noble.com that all information contained in your review is original and accurate in all respects, and that the submission of such content by you and the posting of such content by Barnes & Noble.com does not and will not violate the rights of any third party. Please follow the rules below to help ensure that your review can be posted.

Reviews by Our Customers Under the Age of 13

We highly value and respect everyone's opinion concerning the titles we offer. However, we cannot allow persons under the age of 13 to have accounts at BN.com or to post customer reviews. Please see our Terms of Use for more details.

What to exclude from your review:

Please do not write about reviews, commentary, or information posted on the product page. If you see any errors in the information on the product page, please send us an email.

Reviews should not contain any of the following:

  • - HTML tags, profanity, obscenities, vulgarities, or comments that defame anyone
  • - Time-sensitive information such as tour dates, signings, lectures, etc.
  • - Single-word reviews. Other people will read your review to discover why you liked or didn't like the title. Be descriptive.
  • - Comments focusing on the author or that may ruin the ending for others
  • - Phone numbers, addresses, URLs
  • - Pricing and availability information or alternative ordering information
  • - Advertisements or commercial solicitation

Reminder:

  • - By submitting a review, you grant to Barnes & Noble.com and its sublicensees the royalty-free, perpetual, irrevocable right and license to use the review in accordance with the Barnes & Noble.com Terms of Use.
  • - Barnes & Noble.com reserves the right not to post any review -- particularly those that do not follow the terms and conditions of these Rules. Barnes & Noble.com also reserves the right to remove any review at any time without notice.
  • - See Terms of Use for other conditions and disclaimers.
Search for Products You'd Like to Recommend

Recommend other products that relate to your review. Just search for them below and share!

Create a Pen Name

Your Pen Name is your unique identity on BN.com. It will appear on the reviews you write and other website activities. Your Pen Name cannot be edited, changed or deleted once submitted.

 
Your Pen Name can be any combination of alphanumeric characters (plus - and _), and must be at least two characters long.

Continue Anonymously

    If you find inappropriate content, please report it to Barnes & Noble
    Why is this product inappropriate?
    Comments (optional)