Measurements and Performance Characteristics of Diagnostic X-ray Tubes and Generators (Third Edition): IPEM report 32, part I

This book describes the theoretical principals including potential modes of failures and equipment performance limitations and provides practical advice for making quality assurance (QA) measurements for clinical X-ray tubes and generators. The guidance given for making QA measurements seeks to be practical, using equipment commonly found in medical physics departments, and where possible alternative techniques are discussed along with their relevant limitations. Topics covered include general introduction, requirements for measuring instruments, evaluation of safety features, measurements of beam quality, tube output and consistency, focal spot size, specification for performances, and related ancillaries.

Key Features:

  • The IPEM report 32 series is key UK guidance on the performance of quality assurance procedures across a range of diagnostic and interventional x-ray generating and imaging equipment and often referenced internationally.
  • An update on guidance for medical physics departments for quality assurance measurements for X-ray tubes and generators, considering the advances in technology of X-ray generating equipment.
  • Evidence based where possible, and particularly with reference to the evidence Based QA working party outputs and relevant UK standards.
  • Updated to account for modern measuring devices and techniques (not widely commercially available at the time of publication of the outgoing version but now in widespread common use).
  • Expanded to cover QA of X-ray tube and generator and associated ancillaries not previously covered in Report 32 part I (or the other report 32 series). Areas of expansion include dental X-ray generating equipment, tomography, and key radiation safety features.
1137894821
Measurements and Performance Characteristics of Diagnostic X-ray Tubes and Generators (Third Edition): IPEM report 32, part I

This book describes the theoretical principals including potential modes of failures and equipment performance limitations and provides practical advice for making quality assurance (QA) measurements for clinical X-ray tubes and generators. The guidance given for making QA measurements seeks to be practical, using equipment commonly found in medical physics departments, and where possible alternative techniques are discussed along with their relevant limitations. Topics covered include general introduction, requirements for measuring instruments, evaluation of safety features, measurements of beam quality, tube output and consistency, focal spot size, specification for performances, and related ancillaries.

Key Features:

  • The IPEM report 32 series is key UK guidance on the performance of quality assurance procedures across a range of diagnostic and interventional x-ray generating and imaging equipment and often referenced internationally.
  • An update on guidance for medical physics departments for quality assurance measurements for X-ray tubes and generators, considering the advances in technology of X-ray generating equipment.
  • Evidence based where possible, and particularly with reference to the evidence Based QA working party outputs and relevant UK standards.
  • Updated to account for modern measuring devices and techniques (not widely commercially available at the time of publication of the outgoing version but now in widespread common use).
  • Expanded to cover QA of X-ray tube and generator and associated ancillaries not previously covered in Report 32 part I (or the other report 32 series). Areas of expansion include dental X-ray generating equipment, tomography, and key radiation safety features.
159.0 In Stock
Measurements and Performance Characteristics of Diagnostic X-ray Tubes and Generators (Third Edition): IPEM report 32, part I

Measurements and Performance Characteristics of Diagnostic X-ray Tubes and Generators (Third Edition): IPEM report 32, part I

Measurements and Performance Characteristics of Diagnostic X-ray Tubes and Generators (Third Edition): IPEM report 32, part I

Measurements and Performance Characteristics of Diagnostic X-ray Tubes and Generators (Third Edition): IPEM report 32, part I

eBook

$159.00 

Available on Compatible NOOK devices, the free NOOK App and in My Digital Library.
WANT A NOOK?  Explore Now

Related collections and offers


Overview

This book describes the theoretical principals including potential modes of failures and equipment performance limitations and provides practical advice for making quality assurance (QA) measurements for clinical X-ray tubes and generators. The guidance given for making QA measurements seeks to be practical, using equipment commonly found in medical physics departments, and where possible alternative techniques are discussed along with their relevant limitations. Topics covered include general introduction, requirements for measuring instruments, evaluation of safety features, measurements of beam quality, tube output and consistency, focal spot size, specification for performances, and related ancillaries.

Key Features:

  • The IPEM report 32 series is key UK guidance on the performance of quality assurance procedures across a range of diagnostic and interventional x-ray generating and imaging equipment and often referenced internationally.
  • An update on guidance for medical physics departments for quality assurance measurements for X-ray tubes and generators, considering the advances in technology of X-ray generating equipment.
  • Evidence based where possible, and particularly with reference to the evidence Based QA working party outputs and relevant UK standards.
  • Updated to account for modern measuring devices and techniques (not widely commercially available at the time of publication of the outgoing version but now in widespread common use).
  • Expanded to cover QA of X-ray tube and generator and associated ancillaries not previously covered in Report 32 part I (or the other report 32 series). Areas of expansion include dental X-ray generating equipment, tomography, and key radiation safety features.

Product Details

ISBN-13: 9780750332194
Publisher: Institute of Physics Publishing
Publication date: 12/21/2022
Series: IPEM-IOP Series in Physics and Engineering in Medicine and Biology
Sold by: Barnes & Noble
Format: eBook
Pages: 80
File size: 2 MB

About the Author

Daniel Shaw has over 18 years’ experience working in medical physics departments around the UK and is an experienced radiation protection advisor and medical physics expert for diagnostic and interventional radiology physics. Dan is a member of the IPEM Evidence Based QA working party, former member of IPEM’s Diagnostic Special Interest Group (DRSig) and has contributed to several working parties providing national guidance for the safe clinical use of radiation.

Jason Fazakerley is an experienced radiation protection advisor and medical physics expert at Integrated Radiological Services (IRS) Ltd and an active member of the IPEM Evidence Based QA Working Party.

Debbie Saunders is an experienced medical physics expert in the field of diagnostic and interventional radiology. Debbie is a former chair of IPEM’s Diagnostic Special Interest Group (DRSig) and has contributed to several working parties providing national guidance for the safe clinical use of radiation.

Ian Honey is an experienced medical physics expert and radiation protection advisor. Ian is a former chair of IPEM’s Diagnostic Special Interest Group (DRSig) and chairs the IPEM Evidence Based QA working party and has contributed to several working parties providing national guidance for the safe clinical use of radiation.

Table of Contents

Preface to the First Edition (1980)
Preface to Second Edition (1995)
Preface to the Third Edition (2022)
Acknowledgements
Author biographies
List of contributors

1. Introduction

2. X-ray Tubes and Generators

3. Requirements for Measuring Equipment

4. Equipment Inventory and Service Records

5. Safety Features

6. Collimation alignment and scales

7. Tube Output and Consistency

8. Exposure Time

9. Beam Quality

10. Focal spot

11. Dose area product assessment

12. Focal plane tomography

13. Anti-scatter grids

From the B&N Reads Blog

Customer Reviews