New results in this book show that at the point at which the arc root moves from the contact region, the driven flow could dominate the arc root commutation from the contact region. The arc root contact time analysis and modelling of the magnetic forces lead to able to estimate the minimum forces that moved the arc root from the contact region. The minimum force for the arc to move from the contact region, with contact opening velocities between 1 m/s and 10 m/s, was approximately 0.2 N. Th...